GMDL-02A HV Circuit Breaker Analog Device
GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc.
-
GD2000D Insulation Resistance Tester
GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined.
-
GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester
GDYZ-302 Zinc Oxide Arrester Live Tester is a special instrument used to test the electrical performance of Zinc Oxide Arrester.
-
GDF-3000 DC System Earth Fault Detector
In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault.
-
GDCR1000C Non-contact Phase Sequence Tester
GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method.
-
GDYM-3M Multi-functional Electric Energy Meter Calibrator
The errors, voltage, current, active and reactive power, phase, frequency, and power factor can be measured simultaneously, also vector figure and wiring results will be displayed.
-
GDPQ-5000 Power Quality Analyzer
GDPQ-5000 Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation.
-
GDPQ-300E Power Quality Analyzer
GDPQ-300E Power Quality Analyzer is a portable device of testing and analyzing power system operation quality. It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis.
-
GDCF Series Battery Charge and Discharge Load Bank
This multi-functional instrument provides comprehensive scientific testing method for battery and UPS power supply maintenance. It has charging, discharging, single-unit detection, online monitoring and activation functions. This all-in-one test set reduce the labor intensity of maintenance personnel and enterprise costs.
-
GDKH-12 Lead Acid Battery Regenerator
The device is a special device for activating a valve-regulated lead-acid battery with a battery voltage of 2V, 6V, or 12V and a backward capacity due to sulfide crystallization of an electrode plate.
-
GDUP Series AC Power Supply
The GDUP-6000 (GDUP-3000) is a versatile portable pure sine wave on-site AC test power supply. Also known as on-site AC and DC test power supply, AC and DC emergency power supply, field test power supply, mobile test power supply.
-
DC Power Supply GDWY-250V.15A
It is widely used in power DC system, industrial control, communication, and battery charging equipment and for scientific research.